O General error codes

Type the code from the remote or the indoor unit. The meaning appears on the first character, with every unit type that uses it.

GENERAL's manuals for the exact O General models sit behind a download agreement, so these tables come from GENERAL's published service and installation manuals that share the same code system[1]. We confirm the code on your unit before any repair.

ERROR CODETYPE OR TAP
Type the code from the displayTwo characters, like 41, 5U or A1
Operation Timer Economy
262 rows from 14 GENERAL manualsNo display? Count the blinks

All 51 codes

Where a code means different things on different unit types, each wording is listed with the units it applies to.

Every error code in GENERAL's published tables
CodeLampsMeaning and unit types
11Operation 1
Timer 1
Serial communication error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Serial communication error (Serial reverse transfer error) (Outdoor unit) / Serial communication error (Serial forward transfer error) (Indoor unit)[3][8]
Wall split inverter, 2023 tables, Ducted, high static 3-phase

Serial communication error - reverse transfer outdoor or forward transfer indoor[9]
Large wall split inverter
12Operation 1
Timer 2
Wired remote controller communication error[2][3][8]
Wall split inverter, earlier tables, Wall split inverter, 2023 tables, Ducted, high static 3-phase

Wired remote controller communication error if optional 2-wire remote kit fitted[9]
Large wall split inverter

Wired remote control communication error[5][6][7]
Cassette, Floor or ceiling, Ducted
15Operation 1
Timer 5
Check run unfinished[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Automatic air flow adjustment error (Indoor unit)[8]
Ducted, high static 3-phase
18Operation 1
Timer 8
External communication error[3][9][8]
Wall split inverter, 2023 tables, Large wall split inverter, Ducted, high static 3-phase
21Operation 2
Timer 1
Unit number or Refrigerant circuit address setting error [Simultaneous Multi][2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted
22Operation 2
Timer 2
Indoor unit capacity error[2][3][9][5][6][7]
Wall split inverter, earlier tables, Wall split inverter, 2023 tables, Large wall split inverter, Cassette, Floor or ceiling, Ducted
23Operation 2
Timer 3
Combination error[2][3][9][5][6][7][8]
Wall split inverter, earlier tables, Wall split inverter, 2023 tables, Large wall split inverter, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase
24Operation 2
Timer 4
Connection unit number error (indoor slave unit) [Simultaneous Multi]; Connection unit number error (indoor unit or branch unit) [Flexible Multi][2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted
26Operation 2
Timer 6
Address setting error in wired remote controller (Indoor unit)[3][8]
Wall split inverter, 2023 tables, Ducted, high static 3-phase
27Operation 2
Timer 7
Master unit, slave unit set-up error [Simultaneous Multi][2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted
29Operation 2
Timer 9
Connected unit number error (Indoor unit)[3][8]
Wall split inverter, 2023 tables, Ducted, high static 3-phase
32Operation 3
Timer 2
Indoor unit PCB model information error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Indoor unit main PCB error[3][9][8]
Wall split inverter, 2023 tables, Large wall split inverter, Ducted, high static 3-phase
33Operation 3
Timer 3
Indoor unit motor electricity consumption detection error[3][9][8]
Wall split inverter, 2023 tables, Large wall split inverter, Ducted, high static 3-phase
35Operation 3
Timer 5
Manual auto switch error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

MANUAL AUTO button error[3][9]
Wall split inverter, 2023 tables, Large wall split inverter
39Operation 3
Timer 9
Indoor unit power supply error for fan motor[3][9][8]
Wall split inverter, 2023 tables, Large wall split inverter, Ducted, high static 3-phase
3AOperation 3
Timer 10
Indoor unit communication circuit (wired remote controller) error[3][8]
Wall split inverter, 2023 tables, Ducted, high static 3-phase
41Operation 4
Timer 1
Room temperature sensor error[2][3][9][7][8]
Wall split inverter, earlier tables, Wall split inverter, 2023 tables, Large wall split inverter, Ducted, Ducted, high static 3-phase

Inlet air temp. sensor error[5][6]
Cassette, Floor or ceiling
42Operation 4
Timer 2
Indoor unit Heat Ex. Middle temp. sensor error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Indoor unit heat exchanger sensor error (Indoor unit)[3][8]
Wall split inverter, 2023 tables, Ducted, high static 3-phase

Indoor heat exchanger sensor error[9]
Large wall split inverter
44Operation 4
Timer 4
Human sensor error[3]
Wall split inverter, 2023 tables
51Operation 5
Timer 1
Indoor unit fan motor error[2][3][9][5][6][7][8]
Wall split inverter, earlier tables, Wall split inverter, 2023 tables, Large wall split inverter, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase
53Operation 5
Timer 3
Drain pump error[2][5][6][7][8]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase
57Operation 5
Timer 7
Damper error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted
58Operation 5
Timer 8
Intake grille error[2]
Wall split inverter, earlier tables
5UOperation 5
Timer 15
Indoor unit error[2][5][6][7][8]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase
61Operation 6
Timer 1
Outdoor unit missing phase wire error (Outdoor unit) [listed as 'E: 61.5'; wired display 61][8]
Ducted, high static 3-phase
62Operation 6
Timer 2
Outdoor unit main PCB model information error or communication error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Outdoor unit main PCB error[3][9]
Wall split inverter, 2023 tables, Large wall split inverter

Outdoor unit main PCB error (Outdoor unit) / Outdoor Unit Model Information Error (Outdoor unit)[8]
Ducted, high static 3-phase
63Operation 6
Timer 3
Inverter error[2][3][9][5][6][7][8]
Wall split inverter, earlier tables, Wall split inverter, 2023 tables, Large wall split inverter, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase
64Operation 6
Timer 4
Active filter error, PFC circuit error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

PFC circuit error[3][9][8]
Wall split inverter, 2023 tables, Large wall split inverter, Ducted, high static 3-phase
65Operation 6
Timer 5
Trip terminal L error[2][5][6][7][8]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase

IPM error / trip terminal L error[3][9]
Wall split inverter, 2023 tables, Large wall split inverter
6AOperation 6
Timer 10
Display PCB microcomputers communication error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted
71Operation 7
Timer 1
Discharge temp. sensor error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Discharge thermistor error[3][9][8]
Wall split inverter, 2023 tables, Large wall split inverter, Ducted, high static 3-phase
72Operation 7
Timer 2
Compressor temp. sensor error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Compressor thermistor error[3][9][8]
Wall split inverter, 2023 tables, Large wall split inverter, Ducted, high static 3-phase
73Operation 7
Timer 3
Outdoor unit Heat Ex. liquid temp. sensor error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Outdoor unit heat exchanger thermistor error (Outdoor unit)[3]
Wall split inverter, 2023 tables

Outdoor heat exchanger / middle / outlet thermistor error[9]
Large wall split inverter

Outdoor unit heat exchanger liquid outlet thermistor error (Outdoor unit) / Heat exchanger (Middle/Outlet) temperature thermistor error (Outdoor unit)[8]
Ducted, high static 3-phase
74Operation 7
Timer 4
Outdoor temp. sensor error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Outdoor temperature thermistor error[3][9][8]
Wall split inverter, 2023 tables, Large wall split inverter, Ducted, high static 3-phase
75Operation 7
Timer 5
Suction Gas temp. sensor error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted
76Operation 7
Timer 6
2-way valve temp. sensor error; 3-way valve temp. sensor error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted
77Operation 7
Timer 7
Heat sink temp. sensor error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Heat sink thermistor error[9][8]
Large wall split inverter, Ducted, high static 3-phase
82Operation 8
Timer 2
Sub-cool Heat Ex. gas inlet temp. sensor error; Sub-cool Heat Ex. gas outlet temp. sensor error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted
83Operation 8
Timer 3
Liquid pipe temp. sensor error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted
84Operation 8
Timer 4
Current sensor error[2][3][9][5][6][7][8]
Wall split inverter, earlier tables, Wall split inverter, 2023 tables, Large wall split inverter, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase
86Operation 8
Timer 6
Discharge pressure sensor error; Suction pressure sensor error; High pressure switch error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

High pressure switch error[3][9]
Wall split inverter, 2023 tables, Large wall split inverter

High pressure switch error (Outdoor unit) / Pressure sensor error (Outdoor unit)[8]
Ducted, high static 3-phase
94Operation 9
Timer 4
Trip detection[2][5][6][7][8]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase

Trip detection / over current error[3][9]
Wall split inverter, 2023 tables, Large wall split inverter
95Operation 9
Timer 5
Compressor rotor position detection error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Compressor motor control error[3][9][8]
Wall split inverter, 2023 tables, Large wall split inverter, Ducted, high static 3-phase
97Operation 9
Timer 7
Outdoor unit fan motor error[2][3][9][5][6][7][8]
Wall split inverter, earlier tables, Wall split inverter, 2023 tables, Large wall split inverter, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase
99Operation 9
Timer 9
4-way valve error[2][9][5][6][7][8]
Wall split inverter, earlier tables, Large wall split inverter, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase
A1Operation 10
Timer 1
Discharge temperature error[2][3][9][5][6][7][8]
Wall split inverter, earlier tables, Wall split inverter, 2023 tables, Large wall split inverter, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase
A3Operation 10
Timer 3
Compressor temperature error[2][3][9][5][6][7][8]
Wall split inverter, earlier tables, Wall split inverter, 2023 tables, Large wall split inverter, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase
A4Operation 10
Timer 4
High pressure error[2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted
A5Operation 10
Timer 5
Low pressure error[2][5][6][7][8]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted, Ducted, high static 3-phase
ACOperation 10
Timer 12
Heat sink temperature error[9][8]
Large wall split inverter, Ducted, high static 3-phase
J2Operation 13
Timer 2
Branch boxes error [Flexible Multi][2][5][6][7]
Wall split inverter, earlier tables, Cassette, Floor or ceiling, Ducted

Lamps that are not a fault

  • OPERATION and TIMER flashing together: the unit is in a cooling test run[2].
  • OPERATION blinking slowly while heating: automatic defrost, which can stop the unit for 7 to 15 minutes[10].
  • The unit waits about 3 minutes before restarting after it stops or the power returns[11].

The last error stays in memory

The indoor unit stores the last error even after the power is switched off. A new error replaces it. It clears itself after 2 hours of normal running[3].

Codes not in GENERAL's tables

People search for these, but none of them appear in the GENERAL manuals we checked: 13 16 17 1A 28 31 3B 93 9A 9C E1 EC. Some come from other brands. Check the display again or count the blinks.

Stop the unit when

GENERAL's manual says to stop the unit at once, switch off the breaker and call a technician if you smell burning or the lamps flash fast[12].

Sources

  1. GENERAL Inc. India (general-hvac.com/in, formerly O General / Fujitsu General India): GENERAL (O General) India - RAC Catalogue 2026
  2. Fujitsu General (hosted on General Airstage Australia support portal, article 6000238748): Fujitsu General INSTALLATION MANUAL, Wall Mounted Type, ASTG09KMCA (indoor), PART No. 9333005126
  3. Fujitsu General Limited (hosted on General Airstage Australia support portal, article 6000282865): Fujitsu General SERVICE MANUAL, Wall mounted type, ASTH18/22/24KMTD + AOTH18/22/24KMTD (SR_AS109EF_02)
  4. Fujitsu General (generalww.com, redirected from fujitsu-general.com/shared/ca/): Fujitsu General OPERATION MANUAL, Air Conditioner (Wall-Mounted type) ASUH18/24LPAS, PART No. 9387602265-02
  5. Fujitsu General (hosted on General Airstage Australia support portal, article 6000238601): Fujitsu General SERVICE MANUAL (short form), Split type, CASSETTE TYPE AUTG18LVLA / AOTG18LACC
  6. Fujitsu General (hosted on General Airstage Australia support portal, article 6000238602): Fujitsu General SERVICE MANUAL (short form), ABTG18LVTA / AOTG18LACC (cover text reads 'WALL MOUNTED TYPE'; ABT* = under-ceiling/floor-ceiling family per S13)
  7. Fujitsu General (hosted on General Airstage Australia support portal, article 6000238598): Fujitsu General SERVICE MANUAL (short form), DUCT TYPE ARTG18LLTA / AOTG18LACC
  8. Fujitsu General (hosted on General Airstage Australia support portal, article 6000286646): Fujitsu General SERVICE MANUAL, Duct type High Static Three Phase, ARTH36/45/54/60KHTA + AOTH36/45/54/60KRTA (SR_AR055EF_04)
  9. General Airstage Australia: ASTH30/34KNTA - AOTH30/34KNTA Single Phase Wall Hung R32 Split Systems (technical support article)
  10. GENERAL HVAC Solutions Middle East FZE: GENERAL Middle East & Africa FAQ: Split Systems 0084 / 0039 / 0040 / 0087
  11. GENERAL Inc.: FAQ: split systems, Middle East and Africa
  12. GENERAL Inc.: Operating manual, compact wall mounted type (9332280029-04)